Skip to content

Italy: a map of the ground-mounted fleet

Italy was added on the owner's request on 7 November 2026 with Portugal, Belgium, the Netherlands and Luxembourg, under the rules every recent country follows: no calibration quadrats, no register used, the segmentation localized on Italy's own OpenStreetMap labels and shipped only if it beats the general model on a held-out region. It does, clearly, and this page runs on v34_combined_italy.

Interactive: Italy under Countries.

Headline

Verified 12,175.7 MWp (90% 8,653 to 17,396)
Best estimate 19,972.6 MWp (90% 16,017 to 25,645)
Generation 29.6 TWh/yr from Best (90% 23.7 to 38.0), 1,481 kWh/kWp
Grid 3,193 imaged cells of 0.1°, of the 3,551 that cover the country; 5 macro-regions (geoBoundaries ADM1)
Imagery Sentinel-2 L2A, May to September 2026, median scene 2 August
Model v34_combined_italy, the average of epochs 21 and 29, at threshold 0.7, localized (see below)

A map of the parks, blind to Italy's rooftops

Italy has no calibration quadrats, so there is no roofclf half and no instrument below the 400 m² segmentation floor, and recall was not corrected (--recall-reference none). The energy services operator, GSE, counts 43,687 MW of panels in operation at the end of 2025 (Rapporto Statistico 2025), so Best is about 46% of the fleet. Two thirds of that fleet (29,391 MW) is on buildings, greenhouses and canopies, and the model outlines little of it: Best is 1,612 MWp rooftop (908 MWp more since the large roof leads were judged) and 18,360 MWp ground. GSE's ground-mounted part, 14,296 MW, is the figure to read this page against: Best's ground-mount is 128% of it. Read it as a map of Italy's ground-mounted solar and of what is mapped. Panels imported directly from China, 17.4 GW from January 2017 to August 2026 (Ember), are well below the fleet: Italy built 19.3 GW before 2017 and buys much of the rest through other EU ports, so the page does not call that a ceiling.

Against GSE, by macro-region

GSE publishes its regions; the page's five ADM1 units are ISTAT's macro-regions, so the regions are summed into them (Trentino-Alto Adige as its two provinces). GSE also gives each region's ground-mounted share, which the last column applies, rounded as GSE prints it.

Macro-region Verified (MWp) Best (MWp) GSE, end of 2025 (MW) GSE ground-mounted (MW, approx.) Best as a share of GSE ground
Sud 3,789.3 5,590.6 9,115 4,056 138%
Centro 3,058.9 4,350.8 8,326 3,713 117%
Isole 2,054.5 3,723.9 5,783 3,139 119%
Nord-Est 1,777.3 3,286.9 10,769 1,988 165%
Nord-Ovest 1,270.7 2,641.9 9,695 1,353 195%

Against GSE's totals the ranking runs backwards (Spearman's rho -0.5 on the page): the north, where 82 to 86% of capacity is on buildings, leads GSE's table and trails this one. Against the ground-mounted part the order is the same in all five, and Best lies above it in each, by 17% (Centro) to 95% (Nord-Ovest), since the 297 parks judged on 18 November and the 2,978 large installations judged solar on 19 November (below) count; it was 75% to 121% before them. GSE's figures end in December 2025 and the imagery runs to September 2026. Best also carries 1,612 MWp of rooftop, hand-mapped or judged on the review page, which weighs most against the ground figure in the north. None of these figures is ground truth for this map.

Localizing the detector

The holdout is Nord-Ovest: 576 cells, 1,415 of the country's 9,174 dissolved positives of 400 m² and up (15.4%), chosen by pick_val_region.py from the label map before training; the largest region, Sud, is never the holdout. The localized run kept a snapshot of each late epoch, and pick_checkpoint_by_recall.py chose the average of epochs 21 and 29 at threshold 0.7.

Compared at equal pixel precision (0.55) Local v34 (epochs 21 + 29) General v5
Recall, installations of 500 m² and up (of 3,350) 0.645 0.544
of 1,000 m² and up (of 1,992) 0.664 0.551
of 500 to 1,000 m² (of 1,358) 0.635 0.608
Pixel IoU 0.467 0.362
Pixel F1 0.632 0.533

The local model finds 337 more of the held-out installations and draws them better. The general one needed threshold 0.98 to match its precision.

Plausibility gate

earthpv check-density compares each region's ground-mounted capacity with its rooftop capacity. Four fail and Nord-Ovest is suspect:

Macro-region Rooftop (MWp) Ground (MWp) Ratio Status
Sud 117.7 3,287.7 27.9 fail
Centro 109.4 2,364.4 21.6 fail
Isole 88.9 2,341.0 26.3 fail
Nord-Est 339.6 1,944.5 5.7 fail
Nord-Ovest 330.5 1,504.3 4.6 suspect

The same pattern as France and the Netherlands: the model sees few rooftop arrays, so the denominator is small. The roof leads judged solar on 19 November raised it from 147 to 986 MWp, which took Nord-Ovest from fail to suspect (all five failed before). Whether the model's ground outlines are themselves right has been checked by eye for the unmapped outlines of 1 ha and up that the lead screens put on the two review pages (below); below 1 ha, the agreement with GSE's ground-mounted figures above is the only check so far.

What is counted

  • OpenStreetMap: 28,188 reference features inside the border, placed as 13,880 ground, 11,292 rooftop and 3,016 unknown; after the solar thermal filter and the dissolve 27,703 remain, 9,340 of them 400 m² and up holding 12,040.9 MWp. Verified is all mapped capacity.
  • Model: 18,644 candidates. Best adds 7,796.9 MWp over Verified. Of the 405 outlines above the 100,000 m² merge cap (19.1% of candidate area), the 297 judged solar count whole; the other 108 (5.4%, the largest 1.13 km²) stay out of capacity, 79 judged not solar, 1 left unsure and 28 never on the review page (near mapped solar, or left out by the lead screens). 307 OSM-verified oversize candidates (70.73 km²) are exempt. 79 priced candidates, 9.4 MWp, lie beyond the border in cells kept whole.
  • Judged by a person (the owner, on the two disk review pages). On 18 November, 376 of the 377 outlines above the cap (76.9 km²): 297 are parks, 58.8 km², and each counts whole as ground; 79 are not (one a bright roof), and 1 left unsure stays out and stays on the page. On 19 November, 4,416 of the 4,586 leads from 1 ha up to the cap (129.1 km²): 2,978 solar (86.2 km² of outline, 78.4 km² credited, roofs at ½.5) and 1,438 not (39.2 km², 29 of them bright roofs), which now count nothing; 170 left unsure keep their size bin's price. Roof leads were mostly solar (680 of 754), leads beside buildings mostly so (1,666 of 2,339), leads on open ground about half (632 of 1,323); by macro-region the solar share ran from 59% (Isole) to 75% (Nord-Ovest).
  • Solar thermal: 488 of the 28,188 features were thermal and left the PV count. Three plants tagged as solar thermal with electric output count 2.1 MW, priced from their site area since none states a capacity; one in central Sardinia is probably Ottana's Fresnel plant, the other two are unchecked. Nine thermal plants without electric output are not counted.
  • Footprints: VIDA, with 1,360,247 OSM buildings filling 24,975 empty 0.01° blocks (8.0% of 16,924,117).

What Italy needs next

A rooftop instrument. Areas mapped panel by panel would start a small-installation half, and two thirds of Italy's capacity is on buildings.

The installations judged solar, mapped. Mapping the 297 parks and 2,978 large installations the reviews admitted in OpenStreetMap would move them from Best into Verified; 170 large leads and one blob left unsure wait on the review pages.

The steps still owed. Look at a sample of the model's unmapped ground outlines on high-resolution imagery, publish the mapping leads, and propose calibration areas.

Reproducing

Italy follows Scale to a new country, with the AOI in configs/aoi.yaml and the model in configs/terramind_pv_v34_italy.yaml. The last step:

pixi run earthpv atlas --aoi italy \
  --osm-solar data/labels/italy_national_osm_solar.parquet --include-offgrid-osm \
  --imagery-date-range "May - Sep 2026" --out results/italy_pv_evidence_atlas.html