Netherlands: the parks and the largest roofs, in a country of small rooftops

The Netherlands was added on the owner's request on 7 November 2026 with Portugal, Belgium, Luxembourg and Italy, under the rules every recent country follows: no calibration quadrats, no register used, the segmentation localized on the country's own OpenStreetMap labels and shipped only if it beats the general model on a held-out region. It does not: the general model finds more of the held-out province's installations, so this page runs on v5_combined_france, at the strict threshold that matches the two models on precision. The page covers the European Netherlands.

Interactive: the Netherlands under Countries.

Headline

Verified 3,708.6 MWp (90% 2,710 to 5,198)
Best estimate 4,567.3 MWp (90% 3,711 to 6,109)
Generation 4.9 TWh/yr from Best (90% 4.0 to 6.6), 1,077 kWh/kWp
Grid 541 imaged cells of 0.1°, of the 587 that cover the country; 12 provinces (geoBoundaries)
Imagery Sentinel-2 L2A, May to September 2026, median scene 10 July
Model v5_combined_france epoch 25 at threshold 0.98, general (the localized v32 lost; see below)

Large installations judged before publication

On 10 November the owner judged, on the large installation review, 548 of the 549 unmapped model outlines from 1 ha up to the 10 ha merge cap that the lead screens keep: 543 are solar and 5 are not. 353 of the solar ones are on roofs, where the size class had put the chance of solar near zero. A lead judged solar counts as real (a roof outline at ½.5 of its area, since the model draws about 2.5 times the array) and one judged not solar counts nothing. Best rose from 3,927.2 to 4,567.3 MWp; Verified did not move. Dutch roof outlines sit on their footprints more tightly than elsewhere, so ½.5, measured in Pakistan, may discount them too much.

A precision floor, and blind to most Dutch solar

The Netherlands has no calibration quadrats, so there is no roofclf half and no instrument below the 400 m² segmentation floor, and recall was deliberately not corrected (--recall-reference none), so the arrays the strict threshold misses are not added back. Statistics Netherlands (CBS) counts 29,426.5 MWp of panels at the end of 2025 (85005NED, provisional), so Best is about 16% of the fleet. 12.6 GWp of that is in systems of 15 kWp or less. Read this page as a map of the parks, the largest roofs and what is mapped, not as an estimate of Dutch solar. Panels imported directly from China, 226.7 GW from January 2017 to August 2026 (Ember), are nearly eight times the installed fleet: the Netherlands is the EU's main port of entry for them, so the page does not call that a ceiling.

Against CBS, by province

Province Verified (MWp) Best (MWp) CBS, end of 2025 (MWp) Best as a share of CBS
Noord-Brabant 441.3 607.4 4,998.1 12.2%
Gelderland 508.6 602.0 3,918.7 15.4%
Zuid-Holland 178.1 318.4 3,464.7 9.2%
Noord-Holland 209.9 303.6 2,662.0 11.4%
Overijssel 261.8 303.9 2,395.5 12.7%
Limburg 221.1 304.3 2,222.6 13.7%
Groningen 515.3 544.4 1,984.0 27.4%
Drenthe 427.7 456.1 1,816.1 25.1%
Utrecht 74.8 120.3 1,576.9 7.6%
Fryslân 211.3 234.8 1,470.7 16.0%
Flevoland 302.0 331.9 1,350.2 24.6%
Zeeland 227.4 255.4 1,121.1 22.8%
Netherlands 3,708.6 4,567.3 29,426.5 15.5%

The provinces sum to 3,579.3 MWp Verified and 4,382.5 MWp Best; the rest of the national totals lies in border cells outside them. CBS assigns 445.9 MWp to no province. The shares are highest in Groningen, Drenthe, Flevoland and Zeeland, where large ground-mounted systems are 37% to 50% of CBS's figure, and lowest in Utrecht and the two Hollands, where they are 7% to 13%; Spearman's rho between Best and CBS over the twelve is 0.56. CBS splits its national figure into 6,222.2 MWp of large ground-mounted systems, 10,564.4 MWp of large rooftop systems and 12,639.9 MWp of systems up to 15 kWp; Best places 3,636.1 MWp on the ground and 931.2 MWp on roofs. CBS counts panel (DC) capacity. None of these figures is ground truth for this map.

Localizing the detector

The holdout is Zuid-Holland: 41 cells, 289 of the country's 1,720 dissolved positives of 400 m² and up (16.8%), picked from the label map before training by scripts/pick_val_region.py; Noord-Brabant, the largest, is never the holdout.

The general model never reaches the local model's precision on this holdout, so the two were compared at v5's best, which v5 reaches only at threshold 0.98 and the local model at 0.004:

Compared at equal pixel precision (0.675 to 0.690) Local v32 epoch 4 General v5 at 0.98
Recall, installations of 500 m² and up 0.876 (2,607 of 2,976) 0.918 (2,731)
of which 1,000 m² and up 0.882 0.950
Pixel IoU 0.608 0.578
Pixel F1 0.773 0.721

The general model finds 0.042 more of the installations, past the 0.02 tie band, so it ships under the owner's rule, although the local model draws their outlines better. It ships at threshold 0.98, where a 1 ha lead is 1 ha of near-certain pixels: the owner found only 5 of the 548 judged large leads not solar, against 8% to 22% in Belgium, which runs its own model at 0.3. The cost is the arrays that do not reach 0.98 anywhere, and recall is not corrected for them.

Plausibility gate

earthpv check-density fails 11 of the 12 provinces and flags the twelfth, all on the ratio of ground-mounted to rooftop capacity: segmentation finds 121 MWp on roofs against 2,851 MWp on the ground. As in Belgium, rooftop systems are mostly below what the sensor resolves, so the rooftop denominator is small. Whether the model's unmapped ground outlines are themselves right has not been checked by eye in the Netherlands; Best adds 858.7 MWp over Verified, most of it the judged large roofs.

What is counted

  • OpenStreetMap: 13,882 reference features inside the border after the solar thermal filter, 1,875 of them 400 m² and up. Verified is all mapped capacity.
  • Model: 5,206 candidates. 25 outlines above the 100,000 m² merge cap (5.8% of candidate area, the largest 1.13 km²) are excluded from capacity until judged; 7 of them wait on the solar farm review, none judged yet. 185 OSM-verified oversize parks (44.90 km²) are exempt.
  • Border cells are kept whole: 187 priced candidates (34.4 MWp recall-corrected) lie in Belgium or Germany, in cells the page keeps whole, and its total counts them. A combined atlas does not.
  • Solar thermal: one plant is tagged as solar thermal with electric output, Zoneiland in Almere, and counts 0.5 MW from its site area. Whether it generates electricity rather than heat has not been checked.
  • Footprints: VIDA has large holes in the Netherlands. 2,873,170 OSM buildings fill 7,122 empty 0.01° blocks, 41% of the 6.96 million footprints used.

What the Netherlands needs next

A rooftop instrument. An area mapped panel by panel would start a small-installation half, which here is most of the fleet. CBS publishes capacity per municipality, which could calibrate it as MaStR does Germany's.

The steps still owed. Judge the 7 outlines on the solar farm review, publish the mapping leads, and propose calibration areas.

Reproducing

The Netherlands follows Scale to a new country, with the AOI in configs/aoi.yaml; the localized model that lost is configs/terramind_pv_v32_netherlands.yaml. Density runs at the shipped threshold, then the atlas:

pixi run earthpv density --aoi netherlands --districts --threshold 0.98
pixi run earthpv atlas --aoi netherlands \
  --osm-solar data/labels/netherlands_national_osm_solar.parquet --include-offgrid-osm \
  --imagery-date-range "May - Sep 2026" --out results/netherlands_pv_evidence_atlas.html